Protective adapter for two signal pairs via RJ45 (RJ12) connector or screwed connector
Sturdy metal housing
Two SHDSL ports
Jetzt unverbindlich anfragen!
Preise, Verfügbarkeit oder individuelle Beratung unverbindlich anfragen.
Overview
The DT-TELE-SHDSL Surge Protector was designed to meet the special requirements of SHDSL data transmission. It is specifically designed to provide Lightning, RFI, ESD and transient surge protection for maximum data security with minimum signal attenuation.
Surge protection for SHDSL systems
Reliable telecommunications are indispensable in today’s industry. The sensitive systems used in these cases work with high frequencies at low signal levels and are networked over a wide area. Surge voltages here quickly lead to largescale failures and, in the worst-case scenario, data loss. The SHDSL Surge Protector takes the form of an adapter that can be easily installed between incoming telecommunications cables and a modem. The pluggable connection ensures fast and flexible installation and only needs to be grounded by way of the black cable or DIN rail base.
Attachment plug with surge protection for two SHDSL telecommunications interfaces (ports). Connection: RJ45 (RJ12/RJ11) and plug-in screw terminal block (COMBICON). Alternatively, can be snapped onto a DIN rail.
Hardware Specs
DT-TELE-SHDS Technical Specifications
Ambient Conditions
Ambient temperature (operation)
-40 °C … 85 °C
Ambient temperature (storage/transport)
-40 °C … 85 °C
Degree of protection
IP20
Protective circuit
IEC test classification
B2
C1
C2
C3
D1
Maximum continuous voltage UC
185 V DC
Rated current
≤ 380 mA (25 °C)
Operating effective current IC at UC
≤ 6 µA
Residual current IPE
≤ 4 µA
Nominal discharge current In (8/20) µs (Core-Core)
≤ 5 kA
Nominal discharge current In (8/20) µs (core-earth)
≤ 5 kA
Total discharge current Itotal (8/20) µs
10 kA
Nominal pulse current Ian (10/700) µs (Core-Core)
150 A
Nominal pulse current Ian (10/700) µs (Core-Earth)
150 A
Voltage protection level Up (core-core)
250 V (B2 – 100 A)
≤ 250 V (C1 – 500 A)
≤ 410 V (C2 – 5 kA)
Voltage protection level Up (core-ground)
≤ 580 V (B2 – 100 A)
≤ 580 V (C1 – 500 A)
Response time tA (core-core)
≤ 100 ns
Response time tA (core-earth)
≤ 100 ns
Input attenuation aE, sym.
typ. 0.3 dB (≤ 2,8 MHz / 100 Ω)
typ. 3 dB (≤ 25 MHz / 100 Ω)
Cut-off frequency fg (3 dB), sym. in 100 Ohm system
25 MHz
Capacity (core-core)
55 pF
Capacity (core-earth)
7 pF
Surge protection fault message
None
Impulse durability (conductor-conductor)
C1 – 1 kV/500 A
Impulse durability (conductor-ground)
B2 – 4 kV/100 A
C1 – 1 kV/500 A
C2 – 10 kV/5 kA
VDE requirement class
B2
C1
C2
C3
D1
Maximum continuous voltage UC
130 V AC
Pulse discharge current Iimp (10/350) µs
2.5 kA (Number of pulses category D1)
Nominal pulse current Ian (10/1000) µs (Core-Core)
100 A
Nominal pulse current Ian (10/1000) µs (Core-Earth)
100 A
Voltage protection level Up (core-core)
≤ 250 V (C3 – 100 A)
Voltage protection level Up (core-ground)
≤ 790 V (C2 – 5 kA)
≤ 300 V (C3 – 100 A)
Resistance in series
3.3 Ω 20 %
Impulse durability (conductor-conductor)
C2 – 10 kV/5 kA
B2 – 4 kV/100 A
Impulse durability (conductor-ground)
D1 – 1 kA
Standards and Regulations
Standards / specifications
IEC 61643-21 2002
IEC 61643-21
General
Housing material
Zinc die-cast
Color
silver/black
Mounting type
Connection-specific attachment plug and DIN rail, 35 mm
Digital telecommunications systems (DSL) are safely protected against surge voltage by SHDSL Surge Protectors. Due to the high bandwidth of the surge protectors, the transmission signal is not influenced. Use is possible up to DSL 16000. All signal wires and the ground conductor must be connected to the surge protector according to the connection scheme. Any DIN rail should be grounded.